UPS PRO SRT Series

Uninterruptible Power Supplies Pro SRT Series

Strong points

Safety

High-grade online and line interactive technology guarantees safe and uninterruptible operation of your systems.

Highest possible protection

Online UPS systems provide the highest possible protection against the 10 most frequent mains disturbances.

ADR-UPS-PRO-SRT

Modularity

The individual components of this range can be combined according to requirements and consequently produce specifically defined solutions.

Focus on the future

Our solutions grow with your requirements, can be flexibly used and are easily expanded.

✓ Rack/Tower design
✓ High frequency and true double conversion
✓ DSP digital control technology
✓ Input power factor correction (PFC)
✓ Wide input voltage range (110V-300V)
✓ Output power factor 0.9
✓ Cold start
✓ Frequency adaptive 

✓ ECO mode operation for energy saving
✓ Selectable output voltage via LCD
✓ Output bypass settable for 1,2,3,KVA via LCD
✓ Selectable battery low voltage via LCD
✓ Automatically diagnose when starts
✓ Advanced battery management (ABM)
✓ Short circuit and overload protection 

✓ Automatically charging battery at UPS off mode
✓ Fan speed auto control when load varies
✓ Standard RS232 communication port and RJ45 protection
✓ Optional USB/SNMP communication port
✓ Optional emergency power off (EPO)
✓ Optional extension battery bank

Request your free quote !

Comparative models

MODELADR-901 PRO SRTADR-902 PRO SRTADR-903 PRO SRT
Capacity1KVA / 900W2KVA / 1800W3KVA / 2700W
INPUT
Rated Voltage208V/220V/230V/240VAC208V/220V/230V/240VAC208V/220V/230V/240VAC
Voltage RangeHalf load (115-295) ± 5VAC, Full load (145-295) ± 5VACHalf load (115-295) ± 5VAC, Full load (145-295) ± 5VACHalf load (115-295) ± 5VAC, Full load (145-295) ± 5VAC
Frequency
45-55Hz ± 0.5%Hz or 55-65Hz ± 0.5% Hz (Aoto sensing)45-55Hz ± 0.5%Hz or 55-65Hz ± 0.5% Hz (Aoto sensing)45-55Hz ± 0.5%Hz or 55-65Hz ± 0.5% Hz (Aoto sensing)
Power Factor
≥ 0.98≥ 0.98≥ 0.98
Bypass Voltage Range
Rated output voltage-34V-Rated output voltage+32VRated output voltage-34V-Rated output voltage+32VRated output voltage-34V-Rated output voltage+32V
OUTPUT
Voltage 208V/220V/230V/240VAC Setting avialable via LCD208V/220V/230V/240VAC Setting avialable via LCD208V/220V/230V/240VAC Setting avialable via LCD
Voltage Regulation
± 1%± 1%± 1%
Frequency Synchronized with utility on AC mode ;50/60±0.2Hz on battery modeSynchronized with utility on AC mode ;50/60±0.2Hz on battery modeSynchronized with utility on AC mode ;50/60±0.2Hz on battery mode
Waveform Pure sine wavePure sine wavePure sine wave
Crest Factor
3:13:13:1
Harmonic Distortion
≤3%(Liner load) ; ≤5% (Non-linear load)≤3%(Liner load) ; ≤5% (Non-linear load)≤3%(Liner load) ; ≤5% (Non-linear load)
Transfer Time
AC mode to battery mode : Oms
Inverter model to bypass mode : 4ms (Typical)
AC mode to battery mode : Oms
Inverter model to bypass mode : 4ms (Typical)
AC mode to battery mode : Oms
Inverter model to bypass mode : 4ms (Typical)
Overload Capability
105%-150% : Transfer to bypass after 30s ;
>150% : Transfer to bypass after 300ms
105%-150% : Transfer to bypass after 30s ;
>150% : Transfer to bypass after 300ms
105%-150% : Transfer to bypass after 30s ;
>150% : Transfer to bypass after 300ms
EFFICIENCY
AC Mode
≥90%≥90%≥90%
Battery Mode≥87%≥87%≥87%
ECO Mode ≥98%≥98%≥98%
BATTERY
DC Voltage 24V48V72V
Inbuilt Battery of Standard Model 2 * 9Ah4 * 9Ah6 * 9Ah
Charge Current Standard Model 1A1A1A
Charge Current Long Time Model 6A6A6A
Typical Recharge Time 8 hours recover to 90 % capacity8 hours recover to 90 % capacity8 hours recover to 90 % capacity
ALARM
Utility Failure Beep/4sBeep/4sBeep/4s
Battery Low Beep/1sBeep/1sBeep/1s
Overload Beep Twice/1sBeep Twice/1sBeep Twice/1s
UPS Fault Long BeepLong BeepLong Beep
ENVIRONMENT
Humidity
20~90% RH@ 0~40°C (non-condensing)20~90% RH@ 0~40°C (non-condensing)20~90% RH@ 0~40°C (non-condensing)
Noise Level ≤50Db (1m)≤50Db (1m)≤50Db (1m)
MANAGEMENT
Standard RS-232, Optional USB Supports Windows 98/2000/2003/XP/Vista/2008/Windows 7/8Supports Windows 98/2000/2003/XP/Vista/2008/Windows 7/8Supports Windows 98/2000/2003/XP/Vista/2008/Windows 7/8
Optional SNMP
Power management from SNMP manager and web browserPower management from SNMP manager and web browserPower management from SNMP manager and web browser
PHISICAL
Long Time Model :
- Dimension (mm) W*D*H
- Packing Dimension (mm) W*D*H
- Net/Gross Weight(kg)

440 * 480 * 88

580 * 590 * 200

12.3 / 15.7

440 * 480 * 88

580 * 590 * 200

12.3 / 15.7

440 * 480 * 88

580 * 590 * 200

12.3 / 15.7
Standard Model :
- Dimension (mm) W*D*H
- Packing Dimension (mm) W*D*H
- Net/Gross Weight(kg)

440 * 630 * 88

530 * 710 * 170

29.7 / 33.1

440 * 630 * 88

530 * 710 * 170

29.7 / 33.1

440 * 630 * 88

530 * 710 * 170

29.7 / 33.1